Ruud Logo Background

CAD/BIM

  • Cooling Efficiency: 16 SEER2 / 13 EER2
  • Refrigerant Type: R-454B
  • Nominal Sizes: 1.5 to 5 Tons [TBD kW]
  • Cooling Capacities: 17.1 to 56.0 kBTU
  • Sound Ranking1: As low as 69 dB
  • EcoNet® Enabled: No
  • ENERGY STAR® certified2: Yes
  • Compressor Type: Single Stage
  • Condenser Coil Type: 7mm
  • PlusOnes:
    • PlusOne® Expanded Valve Space: Provides a minimum working area of 27-sqaure inches
    • PlusOne Triple Service Access : 15 in. wide industry leading corner service access, two fastener removeable corner and easily removeable individual louver panels
    • PlusOne® Refrigerant Detection System™3: Integrated, patented design providing system protection and homeowner peace-of-mind with low GWP refrigerant monitoring
  • Limited Warranty*: Conditional Parts: 10 Years (registration required)

*For complete details of the limited and conditional warranties, including applicable terms and conditions, contact your local Contractor or go to Rheem.com for a copy of the product warranty certificate.
1Based on Internal R&D Testing, May 2022. Sound levels are also dependent on proper installation and location of outdoor product.
2Proper sizing and installation of equipment is critical to achieve optimal performance. Ask your contractor for details or visit EnergyStar.gov.
3Factory or field installed in the furnace coil or air handler and is applicable to the complete heating and cooling system featuring Low GWP Refrigerant (A2L).

Unit of Measure

Type

N/A Air Conditioner

Nominal Capacity

N/A 60000 Btu17.58 kW5 TR

Refrigerant Type

N/A R-454B

Refrigerant Furnished oz.

N/A 192

Compressor Type

N/A Scroll

Sound Level

N/A 76 dB

Weight

N/A 266 lb

Voltage

N/A 208 to 230 V

Number of Phases

N/A 1

Frequency

N/A 60 Hz

Maximum Overcurrent Protection

N/A 50 A

Minimum Circuit Ampacity

N/A 31 A

Compressor - Rated Load Amps

N/A 24 A

Compressor - Locked Rotor Amps

N/A 157 A

Condenser Fan Motor - Full Load Amps

N/A 1.0 A

Condenser Fan Motor - Locked Rotor Amps

N/A 2.6 A

Net Face Area - Outer Coil

N/A 27.9 ft²

Net Face Area - Inner Coil

N/A 27.1 ft²

Tube Diameter

N/A 0.276 in

Number of Rows

N/A 2

Fins per Inch

N/A 24

Outdoor Fan Diameter

N/A 26 in

Number of Blades

N/A 3

Motor HP

N/A 1/5 hp

CFM

N/A 4169 ft³/min

RPM

N/A 850

Watts

N/A 245 W

Total Capacity

N/A 56000 Btu16.4 kW

Net Sensible Capacity

N/A 42900 Btu12.6 kW

Net Latent Capacity

N/A 13100 Btu3.8 kW

SEER2

N/A 13.8

EER2

N/A 11.7

Indoor CFM

N/A 1575 ft³/min743.3 L/s

Depth

N/A 35.75 in908 mm

Width

N/A 35.75 in908 mm

Height

N/A 45.00 in1143 mm

Shipping Depth

N/A 38.38 in975 mm

Liquid Line O.D.

N/A 3/8 in

Suction Line O.D.

N/A 7/8 in

N/A

  • 7mm Condenser Copper Coil: Requires less refrigerant allowing for a smaller and lighter footprint while enhancing reliability
  • PlusOne® Expanded Valve Space: 3 in. – 4 in. – 5 in. service valve space – provides a minimum working area of 27-square inches for easier access
  • PlusOne® Triple Service Access: 15 in. wide, industry leading corner service access, two fastener, removeable corner and individual louver panels – makes repairs easier and faster
  • Swept Wing Fan Technology1: Features quieter operation and improved unit acoustics.
  • Designing for Sustainability with Low GWP: For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems. This new requirement will result in a 78%2 lower GWP than previous-generation refrigerants — with only minimal changes to system installation. For us, this is another step toward our continued sustainability goal of reducing greenhouse gas emissions, while still delivering an exceptional level of energy efficient, dependable comfort
  • PlusOne® Refrigerant Detection System™3: An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation — if excess refrigerant is detected

1Does not apply to 1.5 and 2 ton models
2When comparing the GWP of R-454B to R-410A refrigerant
3Factory or field installed in the furnace coil or air handler and is applicable to the complete heating and cooling system featuring Low GWP Refrigerant (A2L)