Ruud Logo Background

CAD/BIM

  • Cooling & Heating Efficiency: 16 SEER2/11.7 EER2/8.1 HSPF2
  • Refrigerant Type: R-454B
  • Nominal Sizes: 1.5 to 5 Tons [TBD kW]
  • Cooling & Heating Capacities: 17.1 to 55.5 kBTU
  • Sound Ranking2: As low as 73 dB
  • EcoNet® Enabled: No
  • ENERGY STAR® certified3: Yes
  • Compressor Type: Two-Stage
  • Condenser Coil Type: 7mm
  • PlusOnes:
    • PlusOne® Expanded Valve Space: Provides a minimum working area of 27-sqaure inches
    • PlusOne Triple Service Access – 15 in. wide industry leading corner service access, two
    • fastener removeable corner and easily removeable individual louver panels
    • PlusOne® Refrigerant Detection SystemTM4- Integrated, patented design providing system
    • protection and homeowner peace-of-mind with low GWP refrigerant monitoring
  • Limited Warranty1: Conditional Parts: 10 Years (registration required)

1For complete details of the limited and conditional warranties, including applicable terms and conditions, contact your local Contractor or go to Rheem.com for a copy of the product warranty certificate.
2Based on Internal R&D Testing, May 2022. Sound levels are also dependent on proper installation and location of outdoor product.
3Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR. Ask your contractor for details or visit EnergyStar.gov.
4Factory or field installed in the furnace coil or air handler and is applicable to the complete heating and cooling system featuring Low GWP Refrigerant (A2L).

Unit of Measure

Type

N/A Air Conditioner

Nominal Capacity

N/A 24000 Btu7.03 kW2.0 TR

Refrigerant Type

N/A R-454B

Refrigerant Furnished oz.

N/A 83

Compressor Type

N/A 2-stage Scroll

Sound Level

N/A 73 dB

Weight

N/A 150 lb

Shipping Weight

N/A 157 lb

Voltage

N/A 208 to 230 V

Number of Phases

N/A 1

Frequency

N/A 60 Hz

Maximum Overcurrent Protection

N/A 25 A

Minimum Circuit Ampacity

N/A 16 A

Compressor - Rated Load Amps

N/A 12 A

Compressor - Locked Rotor Amps

N/A 65 A

Condenser Fan Motor - Full Load Amps

N/A 0.8 A

Condenser Fan Motor - Locked Rotor Amps

N/A 1.5 A

Net Face Area - Outer Coil

N/A 10.9 ft²

Net Face Area - Inner Coil

N/A 10.5 ft²

Tube Diameter

N/A 0.276 in

Number of Rows

N/A 2

Fins per Inch

N/A 22

Outdoor Fan Diameter

N/A 20 in

Number of Blades

N/A 2

Motor HP

N/A 1/6 hp

CFM

N/A 2582 ft³/min

RPM

N/A 1075

Watts

N/A 145 W

Air Handler

N/A RH2TY2417STANN

Total Capacity

N/A 22800 Btu6.7 kW

Net Sensible Capacity

N/A 17500 Btu5.1 kW

Net Latent Capacity

N/A 5300 Btu1.6 kW

SEER2

N/A 15.2

EER2

N/A 11.7

HSPF2

N/A 7.8

Indoor CFM

N/A 775 ft³/min365.8 L/s

Heating Capacity - 47°F

N/A 22600 Btu6.6 kW

Heating Capacity - 17°F

N/A 14000 Btu4.3 kW

COP - 47°F

N/A 3.60

COP - 17°F

N/A 2.50

Depth

N/A 29.75 in756 mm

Width

N/A 29.75 in756 mm

Height

N/A 25.00 in635 mm

Shipping Depth

N/A 33.25 in845 mm

Shipping Width

N/A 33.25 in845 mm

Shipping Height

N/A 27.90 in709 mm

Liquid Line O.D.

N/A 3/8 in

Suction Line O.D.

N/A 3/4 in

N/A

  • Two-Stage Scroll Compressor: Features two speeds high and low) of cooling and heating, providing more precise temperature control, lower humidity and greater efficiency when compared to single stage compressors
  • 7mm Condenser Copper Coil: Requires less refrigerant allowing for a smaller and lighter footprint while enhancing reliability
  • Inverted Reversing Valve: Allows for faster heat transfer with gravity assist shifting and reduced joint stress for increased reliability
  • PlusOne® Expanded Valve Space: 3 in. – 4 in. – 5 in. service valve space — provides a minimum working area of 27-square inches for easier access
  • PlusOne® Triple Service Access: 15 in. wide, industry leading access, two fastener, removeable corner and individual louver panels — makes repairs faster and easier
  • PlusOne® Refrigerant Detection System™1: An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation – if excess refrigerant is detected
  • Designing for Sustainability with Low GWP: For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems. This new requirement will result in a 78%2 lower GWP than previous-generation refrigerants — with only minimal changes to system installation. For us, this is another step toward our continued sustainability goal of reducing greenhouse gas emissions, while still delivering an exceptional level of energy efficient, dependable comfort