Ruud Logo Background

CAD/BIM

  • Cooling & Heating Efficiency: 20 SEER2/12 EER2/8.5 HSPF2
  • Refrigerant Type: R-454B
  • Nominal Sizes: 2 to 5 Tons
  • Cooling & Heating Capacities: 22.8 to 55.0 kBTU
  • Sound Ranking2: As low as 58 dB
  • EcoNet® Enabled: Yes
  • ENERGY STAR(R) Certified*: Yes
  • Compressor Type: Inverter Driven, Variable Speed
  • Condenser Coil Type: 3/8 in.
  • PlusOnes:
    -PlusOne® Diagnostics – Bluetooth® technology aids in quick & easy service
    -PlusOne® Expanded Valve Space: Provides a minimum working area of 27-sqaure inches
    -PlusOne Triple Service Access – 15 in. wide industry leading corner service access, two fastener removeable corner and easily removeable individual louver panels
    -PlusOne® Refrigerant Detection System™1- Integrated, patented design providing system protection and homeowner peace-of-mind with low GWP refrigerant monitoring

Limited Warranty**:
Parts: 10 Years
Conditional Unit Replacement: 10 Years (registration required)

*Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR. Ask your contractor for details or visit www.energystar.gov.
**For complete details of the limited and conditional warranties, including applicable terms and conditions, contact your local Contractor or go to Rheem.com for a copy of the product warranty certificate.
1Factory or field installed in the furnace coil or air handler and is applicable to the complete heating and cooling system featuring Low GWP Refrigerant (A2L).
2Based on manufacturer’s air handler offering, and the product’s airflow stages, motor type and cabinet insulation. Sound levels are also dependent
on air handler location and installation The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Rheem® is under license. Other trademarks and trade names are those of their respective owners.

Unit of Measure

Type

N/A Heat Pump

Nominal Capacity

N/A 60000 Btu/h17.58 kW5.0 TR

Refrigerant Type

N/A R-454B

Refrigerant Furnished oz.

N/A 210

Compressor Type

N/A Variable Speed Scroll

Sound Level

N/A 58 to 73 dB

Weight

N/A 301 lb

Shipping Weight

N/A 309 lb

Voltage

N/A 208 to 230 V

Number of Phases

N/A 1

Frequency

N/A 60 Hz

Minimum Circuit Ampacity

N/A 30 A

Compressor - Rated Load Amps

N/A 25 A

Compressor - Locked Rotor Amps

N/A 50 A

Net Face Area - Outer Coil

N/A 32.5 ft²

Tube Diameter

N/A 0.375 in

Number of Rows

N/A 1

Fins per Inch

N/A 20

Outdoor Fan Diameter

N/A 26 in

Number of Blades

N/A 3

Motor HP

N/A 1/2 hp

Air Handler

N/A RHMVY6021SEACAJ

Total Capacity

N/A 54000 Btu/h15.8 kW

Net Sensible Capacity

N/A 41400 Btu/h12.1 kW

Net Latent Capacity

N/A 12600 Btu/h3.7 kW

SEER2

N/A 5.0

EER2

N/A 5.0

HSPF2

N/A 5.0

Indoor CFM

N/A 1685 ft³/min795.2 L/s

Heating Capacity - 47°F

N/A 54000 Btu/h15.8 kW

Heating Capacity - 17°F

N/A 54000 Btu/h15.8 kW

COP - 47°F

N/A 3.50

COP - 17°F

N/A 2.00

Depth

N/A 36.13 in918 mm

Width

N/A 36.13 in918 mm

Height

N/A 51.17 in1300 mm

Shipping Depth

N/A 39.37 in1000 mm

Shipping Width

N/A 39.64 in1007 mm

Shipping Height

N/A 53.56 in1360 mm

Liquid Line O.D.

N/A 3/8 in

Suction Line O.D.

N/A 7/8 in

N/A

  • EcoNet® Enabled: Automatic system configuration and optimization
  • PlusOne® Diagnostics & Bluetooth®1 Connectivity: With the Rheem Contractor & EcoNet® Apps, built-in technology makes advanced set-up, monitoring, troubleshooting, and repairing the product easier than ever before
  • Variable Speed Scroll Compressor & Inverter Drive:
    — Features variable speed operation from 40 to 100% capacity with the EcoNet® Smart Thermostat
    — Offers overdrive capability up to 115% to maintain performance in extreme conditions
    — Provides precise temperature control, advanced humidity control and greater efficiency
  • Brushless DC Condenser Motors (BLDC): Enhances reliability and allows for easier serviceability
  • Swept Wing Fan Technology: Features quieter operation and improved unit acoustics
  • Designing for Sustainability with Low GWP: For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems. This new requirement will result a 78%2 lower GWP than previous-generation refrigerants — with only minimal changes to system installation. For us, this is another step toward our continued sustainability goal of educing greenhouse gas emissions, while still delivering an exceptional level of energy efficient, dependable comfort
  • PlusOne® Refrigerant Detection System™3: An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation – if excess efrigerant is detected
1The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Rheem is under license. Other trademarks and trade names are those of their respective owners.
2When comparing the GWP of R-454B to R-410A refrigerant.
3Factory or field installed in the furnace coil or air handler and is applicable to the complete heating and cooling system featuring Low GWP Refrigerant (A2L).