CAD/BIM
RHPH, Resolute™ 15-20 Ton
Packaged Heat Pump
- Up to 13.5 IEER / 10.6 EER
- Up to 3.3 COP
- Two-Stage Cooling
- Variable Frequency Drive
- 3 Phase Models
- PlusOne® ServiceSmart
- Nominal Sizes: 15-20 Tons
Unit of Measure
Items |
RHPH2T180 RHPH2T180 - Rheem Packaged 15T HP |
RHPH2T240 RHPH2T180 - Rheem Packaged 20T HP |
||
Type | N/A Package HP | |||
Gross Cooling Capacity | N/A 180000 Btu/h52.8 kW15 TR | N/A 240000 Btu/h70.3 kW20 TR | ||
EER | N/A 10.6 | N/A 9.5 | ||
IEER | N/A 13.5 | N/A 12.5 | ||
Nominal CFM | N/A 6000 ft³/min2831 L/s | N/A 8000 ft³/min3775 L/s | ||
AHRI Rated CFM | N/A 6450 ft³/min3044 L/s | N/A 8200 ft³/min3870 L/s | ||
AHRI Net Cooling Capacity | N/A 172000 Btu/h50.4 kW | N/A 240000 Btu/h70.3 kW | ||
Net Sensible Capacity | N/A 144000 Btu/h42.2 kW | N/A 188000 Btu/h55.1 kW | ||
Net Latent Capacity | N/A 28000 Btu/h8.2 kW | N/A 52000 Btu/h15.2 kW | ||
Minimum Circuit Ampacity | N/A 208-230V Belt Drive-VFD Low: 75 A 208-230V Belt Drive-VFD Medium: 80 A 460V Belt Drive-VFD Low: 37 A 460V Belt Drive-VFD Medium: 38 A 575V Belt Drive-VFD Low: 28 A 575V Belt Drive-VFD Medium: 30 A | N/A 208-230V Belt Drive-VFD High: 114 A 208-230V Belt Drive-VFD Low: 107 A 208-230V Belt Drive-VFD Medium: 114 A 460V Belt Drive-VFD High: 51 A 460V Belt Drive-VFD Low: 47 A 460V Belt Drive-VFD Medium: 51 A 575V Belt Drive-VFD High: 42 A 575V Belt Drive-VFD Low: 39 A 575V Belt Drive-VFD Medium: 42 A | ||
Maximum Overcurrent Protection | N/A 208-230V: 100 A 460V: 45 A 575V: 35 A | N/A 208-230V Belt Drive-VFD High: 150 A 208-230V Belt Drive-VFD Low: 125 A 208-230V Belt Drive-VFD Medium: 150 A 460V: 60 A 575V: 50 A | ||
Voltage | N/A 3 / 208-230V / 60Hz 3 / 460V / 60Hz 3 / 575V / 60Hz | |||
Depth | N/A 85 29/32 in2182 mm | |||
Width | N/A 152 1/4 in3667 mm | |||
Height | N/A 57 1/8 in1451 mm | |||
Weight | N/A 208-230V Belt Drive-VFD Low: 1826 lb [828 kg] 208-230V Belt Drive-VFD Medium: 1855 lb [841 kg] 460V Belt Drive-VFD Low: 1958 lb [888 kg] 460V Belt Drive-VFD Medium: 1987 lb [901 kg] 575V Belt Drive-VFD Low: 1826 lb [838 kg] 575V Belt Drive-VFD Medium: 1855 lb [841 kg] | N/A 208-230V Belt Drive-VFD High: 1894 lb [859 kg] 208-230V Belt Drive-VFD Low: 1865 lb [846 kg] 208-230V Belt Drive-VFD Medium: 1894 lb [859 kg] 460V Belt Drive-VFD High: 1894 lb [904 kg] 460V Belt Drive-VFD Low: 1865 lb [846 kg] 460V Belt Drive-VFD Medium: 1894 lb [859 kg] 575V Belt Drive-VFD High: 1894 lb [859 kg] 575V Belt Drive-VFD Low: 1865 lb [846 kg] 575V Belt Drive-VFD Medium: 1894 lb [859 kg] | ||
Shipping Weight | N/A 208-230V Belt Drive-VFD Low: 1926 lb [874 kg] 208-230V Belt Drive-VFD Medium: 1955 lb [887 kg] 460V Belt Drive-VFD Low: 2058 lb [934 kg] 460V Belt Drive-VFD Medium: 2087 lb [947 kg] 575V Belt Drive-VFD Low: 1926 lb [874 kg] 575V Belt Drive-VFD Medium: 1955 lb [887 kg] | N/A 208-230V Belt Drive-VFD High: 1994 lb [904 kg] 208-230V Belt Drive-VFD Low: 1965 lb [891 kg] 208-230V Belt Drive-VFD Medium: 1994 lb [904 kg] 460V Belt Drive-VFD High: 1994 lb [904 kg] 460V Belt Drive-VFD Low: 1965 lb [891 kg] 460V Belt Drive-VFD Medium: 1994 lb [904 kg] 575V Belt Drive-VFD High: 1994 lb [904 kg] 575V Belt Drive-VFD Low: 1965 lb [891 kg] 575V Belt Drive-VFD Medium: 1994 lb [904 kg] | ||
|
Ruud is a part of the Rheem® family of brands. In keeping with its policy of continuous progress & program improvement, Rheem reserves the right to make changes without notice. © 2024 Rheem Manufacturing Company Ruud trademarks are owned by Ruud Manufacturing Company. Rheem and other trademarks are owned by Rheem Manufacturing Company or its affiliates.