Ruud Logo Background

CAD/BIM

  • Constant CFM Motor:
    — When paired with EcoNet® Smart Thermostat, gradually auto-adjusts from low capacity to 100% of capacity to meet comfort requirements—allowing for ultimate humidity control, quieter sounds levels and year-round energy savings
    — When paired with 24V two-stage thermostat, air handler runs in 2 speeds to match airflow with outdoor unit
  • Quieter Operation1: Provided by two-stage operation and truly variable speed airflow technology and sturdy cabinet construction with 1.0 inch of foil faced insulation for quieter sound characteristics
  • PlusOne® Diagnostics: With the Rheem Contractor & EcoNet® Apps, built-in EcoNet® & Bluetooth® technology makes monitoring, troubleshooting and repairing the product easier than ever before
  • Dip Switch Free Installation Commissioning via Bluetooth® Technology: Seamless final install step without DIP switch configuration using the Rheem Contractor App
  • EcoNet® Enabled Air Handler:
    — The latest in sensor technology and the EcoNet® monitoring system provides a new level of protection, control and energy savings
    — Allows on-the-go control and receipt of system alerts by the homeowner via the EcoNet Smart Technology and EcoNet App2
  • Aluminum Indoor Coil Design: Are constructed of aluminum fins bonded to internally grooved aluminum tubing and are more corrosion resistant
  • Versatile 4-Way Convertible Compact Design: Allows for upflow, downflow, horizontal left and horizontal right applications, even in the smallest of spaces
  • Rugged Steel, Compact Cabinet Construction: Designed for added strength and versatility
  • Field-installed Auxiliary Heater Kits: Provide exact heat for indoor comfort and include circuit breakers which meet UL and cUL requirements for service disconnect
  • Cabinet air leakage: less than 2% at 1 inch H2O when tested in accordance with ASHRAE Standard 19
  • Designing for Sustainability with Low GWP: For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems. This new requirement will result in a 78%3 lower GWP than previous-generation refrigerants — with only minimal changes to system installation. For us, this is another step toward our continued sustainability goal of reducing greenhouse gas emissions, while still delivering an exceptional level of energy efficient, dependable comfort
  • PlusOne® Refrigerant Detection System™4: An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation — if excess refrigerant is detected
  • Limited Warranty*: Conditional Parts: 10 Years (registration required)

    1Based on manufacturer’s air handler offering, and the product’s airflow stages, motor type and cabinet insulation. Sound levels are also dependent on air handler location and installation.
    2Wifi broadband internet connection required. Download the EcoNet® App from the App Store® or Google Play® to set up your EcoNet® Smart Thermostat. Receipt of notifications depend on home WiFi set up. Amazon, Alexa and all related logos are trademarks of Amazon.com, Inc. or its affiliates.
    3When comparing the GWP of R-454B to R-410A refrigerant
    4Factory or field installed in the furnace coil or air handler and is applicable to the complete heating and cooling system featuring Low GWP Refrigerant (A2L)
    *For complete details of the limited and conditional warranties, including applicable terms and conditions, contact your local Contractor or go to Rheem.com for a copy of the product warranty certificate.
    *The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Rheem® is under license. Other trademarks and trade names are those of their respective owners.

Unit of Measure

Type

N/A Multipurpose Air Handler

Voltage

N/A 208 to 240 V

Number of Phases

N/A 1

Frequency

N/A 60 Hz

Stages of Airflow

N/A Two-Stage

Motor Type

N/A Constant CFM

Refrigerant

N/A R-454B

Nominal Capacity

N/A 36000 Btu/h10.55 kW

Efficiency

N/A Mid

Metering

N/A TXV

Controls

N/A Communicating

Coil Series

N/A N Coil

Blower Motor

N/A 1/2 hp

Blower Motor - RPM

N/A 300 to 1300

Motor Amps

N/A 3.9 A

Minimum Circuit Ampacity

N/A 5 A

Maximum Overcurrent Protection

N/A 15 A

Weight

N/A 126 lb57 kg

Shipping Weight

N/A 142 lb64 kg

Depth

N/A 21 11/16 in551 mm

Width

N/A 21 in533 mm

Height

N/A 50 1/2 in1282 mm

Suply Duct

N/A 19 1/2 in495 mm

Refrigerant Connections Sweat ID - Liquid

N/A 3/8 in9.53 mm

Refrigerant Connections Sweat ID - Vapor

N/A 7/8 in22.23 mm

N/A

  • Constant CFM Motor:
    — When paired with EcoNet® Smart Thermostat, gradually auto-adjusts from low capacity to 100% of capacity to meet comfort requirements— allowing for ultimate humidity control, quieter sounds levels and year-round energy savings
    — When paired with 24V two-stage thermostat, air handler runs in 2 speeds to match airflow with outdoor unit
  • Quieter Operation1: Provided by two-stage operation and truly variable speed airflow technology and sturdy cabinet construction with 1.0 inch of foil faced insulation for quieter sound characteristics
  • PlusOne® Diagnostics: With the Rheem Contractor & EcoNet® Apps, built-in EcoNet® & Bluetooth® technology makes monitoring, troubleshooting and repairing the product easier than ever before
  • Dip Switch Free Installation Commissioning via Bluetooth® Technology: Seamless final install step without DIP switch configuration using the Rheem Contractor App
  • EcoNet® Enabled Air Handler:
    — The latest in sensor technology and the EcoNet® monitoring system provides a new level of protection, control and energy savings
    — Allows on-the-go control and receipt of system alerts by the homeowner via the EcoNet® Smart Thermostat and EcoNet® App2
  • Aluminum Indoor Coil Design: Are constructed of aluminum fins bonded to internally grooved aluminum tubing and are more corrosion resistant
  • Versatile 4-Way Convertible Compact Design: Allows for upflow, downflow, horizontal left and horizontal right applications, even in the smallest of spaces
  • Rugged Steel, Compact Cabinet Construction: Designed for added strength and versatility
  • Field-installed Auxiliary Heater Kits: Provide exact heat for indoor comfort and include circuit breakers which meet UL and cUL requirements for service disconnect
  • Less than 2% Cabinet Air Leakage at 1-inch H2O: When tested in accordance with ASHRAE Standard 193
  • Designing for Sustainability with Low GWP: For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems. This new requirement will result in a 78%3 lower GWP than previous-generation refrigerants — with only minimal changes to system installation. For us, this is another step toward our continued sustainability goal of reducing greenhouse gas emissions, while still delivering an exceptional level of energy efficient, dependable comfort
  • PlusOne® Refrigerant Detection System™4: An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation — if excess refrigerant is detected

1Based on manufacturer’s air handler offering, and the product’s airflow stages, motor type and cabinet insulation. Sound levels are also dependent on air handler location and installation.
2Wifi broadband internet connection required. Download the EcoNet® App from the App Store® or Google Play® to set up your EcoNet® Smart Thermostat. Receipt of notifications depend on home WiFi set up. Amazon, Alexa and all related logos are trademarks of Amazon.com, Inc. or its affiliates.
3When comparing the GWP of R-454B to R-410A refrigerant
4Factory or field installed in the furnace coil or air handler and is applicable to the complete heating and cooling system featuring Low GWP Refrigerant (A2L).