Ruud Logo Background

CAD/BIM

  • Quiet Operation1: Provided by a cabinet construction with 1.0 inch of foil faced insulation for quieter sound characteristics
  • Aluminum Indoor Coil Design: Are constructed of aluminum fins bonded to internally grooved aluminum tubing and are more corrosion resistant
  • Versatile 4-Way Convertible Compact Design: Allows for upflow, downflow, horizontal left and horizontal right applications, even in the smallest of spaces
  • Rugged Steel, Compact Cabinet Construction: Designed for added strength and versatility
  • Field-installed Auxiliary Heater Kits: Provide exact heat for indoor comfort and include circuit breakers which meet UL and cUL requirements for service disconnect
  • Cabinet air leakage: less than 2% at 1 inch H2O when tested in accordance with ASHRAE Standard 19
  • Designing for Sustainability with Low GWP: For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems. This new requirement will result in a 78%2 lower GWP than previous-generation refrigerants — with only minimal changes to system installation. For us, this is another step toward our continued sustainability goal of reducing greenhouse gas emissions, while still delivering an exceptional level of energy efficient, dependable comfort
  • PlusOne® Refrigerant Detection System™3: An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation — if excess refrigerant is detected
  • Limited Warranty*: Conditional Parts: 10 Years (registration required)

*For complete details of the limited and conditional warranties, including applicable terms and conditions, contact your local Contractor or go to Rheem.com for a copy of the product warranty certificate.
1Based on manufacturer’s air handler offering, and the product’s airflow stages, motor type and cabinet insulation. Sound levels are also dependent on air handler location and installation
2When comparing the GWP of R-454B to R-410A refrigerant
3Factory or field installed in the furnace coil or air handler and is applicable to the complete heating and cooling system featuring Low GWP Refrigerant (A2L)

Unit of Measure

Type

N/A Multipurpose Air Handler

Voltage

N/A 115 V

Number of Phases

N/A 1

Frequency

N/A 60 Hz

Stages of Airflow

N/A 1-Stage

Motor Type

N/A PSC

Refrigerant

N/A R-454B

Nominal Capacity

N/A 42000 Btu12.31 kW

Efficiency

N/A Standard

Metering

N/A TXV

Controls

N/A Non-communicating

Coil Series

N/A N Coil

Air Flow - Lo

N/A 1400 ft³/min661 L/s

Air Flow - Hi

N/A 1600 ft³/min755 L/s

Blower Motor

N/A 1/2 hp

Blower Motor - RPM

N/A 1075

Blower Motor - Speed

N/A 2

Motor Amps

N/A 7.9 A

Minimum Circuit Ampacity

N/A 10 A

Maximum Overcurrent Protection

N/A 15 A

Weight

N/A 130 lb59 kg

Shipping Weight

N/A 146 lb66 kg

Depth

N/A 19 1/2 in495 mm

Width

N/A 21 in533 mm

Height

N/A 50 1/2 in1282 mm

Refrigerant Connections Sweat ID - Liquid

N/A 3/8 in9.53 mm

Refrigerant Connections Sweat ID - Vapor

N/A 7/8 in22.23 mm

N/A

  • Quiet Operation1: Provided by a cabinet construction with 1.0 inch of foil faced insulation for quieter sound characteristics
  • Aluminum Indoor Coil Design: Are constructed of aluminum fins bonded to internally grooved aluminum tubing and are more corrosion resistant
  • Versatile 4-Way Convertible Compact Design: Allows for upflow, downflow, horizontal left and horizontal right applications, even in the smallest of spaces
  • Rugged Steel, Compact Cabinet Construction: Designed for added strength and versatility
  • Field-installed Auxiliary Heater Kits: Provide exact heat for indoor comfort and include circuit breakers which meet UL and cUL requirements for service disconnect
  • Cabinet air leakage less than 2% at 1 inch H2O when tested in accordance with ASHRAE Standard 193
  • Designing for Sustainability with Low GWP: For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems. This new requirement will result in a 78%2 lower GWP than previous-generation refrigerants — with only minimal changes to system installation. For us, this is another step toward our continued sustainability goal of reducing greenhouse gas emissions, while still delivering an exceptional level of energy efficient, dependable comfort
  • PlusOne® Refrigerant Detection System™3: An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation — if excess refrigerant is detected

1Based on manufacturer’s air handler offering, and the product’s airflow stages, motor type and cabinet insulation. Sound levels are also dependent on air handler location and installation.
2When comparing the GWP of R-454B to R-410A refrigerant
3Factory or field installed in the furnace coil or air handler and is applicable to the complete heating and cooling system featuring Low GWP Refrigerant (A2L).