Ruud Logo Background

CAD/BIM

  • Scroll Compressors on all models: Provides maximum efficiency and quiet operation.
  • MicroChannel Evaporator & Condenser Coil: Delivers superior performance with a robust surface, a decreased refrigerant requirement and is lighter than conventional copper tube/aluminum fin coils.All-aluminum construction offers superior protection against formicary corrosion and aluminum tube rubbing damage. Design allows for easier and faster cleaning.
  • Thermal Expansion Valves: Standard on all models for precise superheat control, reliability, and energy efficiency at all operating conditions.
  • High Pressure Control: Standard on all models for refrigerant component protection and reliability.
  • Easily Accessible Control Box and Slide-Out Blower Section Allows for faster installability and serviceability.
  • Supplemental Electric Heating Option Available: Field-Installed, electrical heat strips, up to 15 kW with simplified single-point wiring, are available for periods of extreme weather conditions.
  • Tested. Trusted. Tough. 100% Factory Run Tested.
  • PlusOne® Refrigerant Detection System™1 Integrated, patented design providing system protection and homeowner peace-of-mind with low GWP refrigerant monitoring

1Factory installed on 3.5, 4 and 5 ton AC models and all tonnages on HP models. For R-454B equipment with a refrigerant charge less than 3.9 lbs (≈1.8 kg or ≈62.6 oz), a refrigerant detection system is not required by the UL 60335-2-40 standard.

Unit of Measure

Voltage

N/A 208/230 V

Frequency

N/A 60 Hz

Number of Phases

N/A 1

Outdoor Sound Rating

N/A 79 dB

Refrigerant Charge

N/A 46.4 oz1315 g

Minimum Circuit Ampacity

N/A 22

Minimum Overcurrent Protection Device Size

N/A 25

Maximum Overcurrent Protection Device Size

N/A 30

Shipping Weight

N/A 362 lb164 kg

Weight

N/A 161 kg354 lb

Gross Cooling Capacity

N/A 29400 Btu/h8.61 kW

EER2

N/A 10.6

SEER2

N/A 13.4

Nominal CFM

N/A 1000 ft³/min472 L/s

AHRI Rated CFM

N/A 980 ft³/min462 L/s

AHRI Net Cooling Capacity

N/A 28400 Btu/h8.32 kW

Net Sensible Cooling Capacity

N/A 21100 Btu/h6.18 kW

Net Latent Cooling Capacity

N/A 7300 Btu/h2.14 kW

Net System Power

N/A 2.45 kW

Type

N/A Single-Stage Scroll

No. Stages

N/A 1

Fin Type

N/A Louvered

Tube Type

N/A MicroChannel

MicroChannel Depth

N/A 0.709 in18 mm

Face Area

N/A 7.06 ft²0.66 m²

Rows

N/A 1

FPI

N/A 23

Fin Type

N/A Louvered

Tube Type

N/A MicroChannel

MicroChannel Depth

N/A 1 in25.4 mm

Face Area

N/A 3.54 ft²0.33 m²

Rows

N/A 1

FPI

N/A 20

Refrigerant Control

N/A TX Valves

Drain Connection No.

N/A 1

Drain Connection Size

N/A 0.75 in19.05 mm

Type

N/A Propeller

No. Used

N/A 1

Diameter

N/A 22 in558.8 mm

Drive Type

N/A Direct

No. Speeds

N/A 1

CFM

N/A 2400 ft³/min1133 L/s

No. Motors

N/A 1

Horsepower

N/A 1/3 hp

Motor RPM

N/A 825

Type

N/A FC Centrifugal

No. Used

N/A 1

Diameter

N/A 10x9 in254x229 mm

Drive Type

N/A Direct

No. Speeds

N/A Multiple

No. Motors

N/A 1

Motor HP

N/A 1/2 hp

Motor RPM

N/A 1050

Motor Frame Size

N/A 48

Type

N/A Disposable

Furnished

N/A No

No. Filters

N/A 1

Recommended Size

N/A 1x24x24 in25x610x610 mm

Depth

N/A 50 13/16 in

Width

N/A 47 1/2 in

Height

N/A 35 15/16 in

N/A

  • Scroll Compressors on all models: Provides maximum efficiency and quiet operation
  • MicroChannel Evaporator and Condenser Coil: Delivers superior performance with a robust surface, a decreased refrigerant requirement and is lighter than conventional copper tube/aluminum fin coils. All-aluminum construction offers superior protection against formicary corrosion and aluminum tube rubbing damage. The design allows for easier and faster cleaning
  • Thermal Expansion Valves: Standard on all models for precise superheat control, reliability, and energy efficiency at all operating conditions
  • High Pressure Control: Standard on all models for refrigerant component protection and reliability
  • Filter Drier: Standard on all models
  • 100% Factory Run Tested
  • PlusOne® Refrigerant Detection System™: An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation — if excess refrigerant is detected
  • Rugged Base Rail: For improved installation and handling
  • Easily Accessible Control Box and Blower Section with Slide-Out Blower
  • Slide and Down Discharge Options Available: All models are shipped ready for horizontal applications
  • Double Sloped Evaporator Coil Drain Pan: Assures all water is removed from the unit to improve indoor air quality
  • Louvered Condenser Compartment: Protects the coil against yard hazards and/or weather extremes
  • Supply and Return Air Openings: Feature a one-inch-tall flange to prevent water migration into the ductwork
  • Supplemental Electric Heating Option Available: Fieldinstalled, electrical heat strips, up to 15 kW with simplified single-point wiring, are available for periods of extreme weather conditions
  • Designing for Sustainability with Low GWP: For 2025, the environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems. This new requirement will result in a 78%1 lower GWP than previous-generation refrigerants with only minimal changes to system installation. For us, this is another step toward our continued sustainability goal of reducing greenhouse gas emissions, while still delivering an exceptional level of energy efficient, dependable comfort