  • Nominal sizes: 7.5, 10, 12.5, 15 & 20 Tons
  • For use with matching RACY Models
  • Horizontal or vertical airflow
  • Refrigerant Type: R-454B with factory-installed sensor
Unit of Measure
Items
Ruud-RHCYA2090_2121-CommSplitAH-Front-HERO-LeftFacing

RHCYA Commercial Split Achiever® Series A/C Air Handler

Ruud-RHCYA2090_2121-CommSplitAH-Front-HERO-LeftFacing

RHCYA Commercial Split Achiever® Series A/C Air Handler

Ruud-RHCYA2090_2121-CommSplitAH-Front-HERO-LeftFacing

RHCYA Commercial Split Achiever® Series A/C Air Handler

Ruud-RHCYA2090_2121-CommSplitAH-Front-HERO-LeftFacing

RHCYA Commercial Split Achiever® Series A/C Air Handler

Ruud-RHCYA2090_2121-CommSplitAH-Front-HERO-LeftFacing

RHCYA Commercial Split Achiever® Series A/C Air Handler
Nominal Cooling Capacity N/A 90000 Btu/h26 kW7.5 TR N/A 120000 Btu/h35 kW10 TR N/A 120000 Btu/h35 kW10 TR N/A 150000 Btu/h44 kW12.5 TR N/A 180000 Btu/h53 kW15 TR
Nominal CFM N/A 3000 ft³/min1416 L/s N/A 4000 ft³/min1888 L/s N/A 4000 ft³/min1888 L/s N/A 4785 ft³/min2258 L/s N/A 6000 ft³/min2832 L/s
Rated E.S.P. N/A 0.25 N/A 0.3 N/A 0.3 N/A 0.35 N/A 0.35
Motor Horsepower - Standard (1725 RPM) N/A 2 hp
Motor Horsepower - Optional (1725 RPM) N/A 2 hp3 hp N/A 2 hp3 hp N/A 2 hp3 hp N/A 2 hp3 hp5 hp N/A 2 hp3 hp5 hp
Blower Diameter N/A 12 in N/A 12 in N/A 18 in N/A 18 in N/A 18 in
Blower Width N/A 12 in N/A 12 in N/A 15 in N/A 15 in N/A 15 in
Blower Shaft Size N/A 3/4 in N/A 3/4 in N/A 1 in N/A 1 in N/A 1 in
Motor Sheave Size (1725 RPM) N/A 1VL44x7/8" N/A 1VP56X7/8" N/A 1VP40x7/8" N/A 1VL44x7/8" N/A 1VL44x7/8"
Belt Type and Size N/A A-50 N/A V-54 N/A B52 N/A B52 N/A B52
Coil Face Area N/A 10.2 ft² N/A 10.2 ft² N/A 16.2 ft² N/A 16.2 ft² N/A 16.2 ft²
Coil Tube Diameter N/A 3/8 in
Coil Rows Deep N/A 4 in N/A 4 in N/A 3 in N/A 3 in N/A 4 in
Fins Per Inch N/A 15
Refrigerant Control—Thermal Expansion Valves N/A BBIZE-5-GA N/A BBIZE-7-CP N/A HXAE-8-KXB N/A BBIYE-8.5-CP N/A BBIYE-8.5-CP
Refrigerant Control—Thermal Expansion Valves No. N/A 2
Filter Size N/A 16 x 25 x 1 N/A 16 x 25 x 1 N/A 20 x 25 x 1 N/A 20 x 25 x 1 N/A 20 x 25 x 1
Filter - No. Filters N/A 4 N/A 4 N/A 6 N/A 6 N/A 6
Gauge - Top N/A 18 in
Gauge - Sides N/A 16 in
Gauge - Bottom N/A 18 in
Gauge - Doors and Covers N/A 20 in
Voltage N/A 230 V
Frequency N/A 60 Hz
Number of Phases N/A 3
Depth N/A 52 in N/A 52 in N/A 59.5 in N/A 59.5 in N/A 59.5 in
Width N/A 52 in N/A 52 in N/A 72 in N/A 72 in N/A 72 in
Height N/A 27 in N/A 27 in N/A 34.25 in N/A 34.25 in N/A 34.25 in
Weight N/A 409 lb186 kg N/A 409 lb186 kg N/A 575 lb261 kg N/A 575 lb261 kg N/A 690 lb313 kg
Shipping Weight N/A 429 lb195 kg N/A 429 lb195 kg N/A 595 lb270 kg N/A 595 lb270 kg N/A 710 lb322 kg
Features N/A
    The RHCYA Series air handler features a modular design, allowing for easier transportation and installation, reducing labor costs and downtime during setup. Models are also compatible with MERV8 and MERV13 filters for enhanced building IAQ. Designed for use with matching RACY models only.
    Available power options: 208-230V / 3 phase / 60 Hz • 460V / 3 phase / 60 Hz • 575V / 3 phase / 60 Hz
    Limited Warranty (Commercial Applications): Parts – 1 Year. Additional extended warranty packages available through ProtectionPlus®.