Ruud Logo Background

CAD/BIM

  • Two-Stage Scroll Compressors on all models: Provides maximum efficiency and quiet operation.
  • MicroChannel Evaporator & Condenser Coil: Delivers superior performance with a robust surface, a decreased refrigerant requirement and is lighter than conventional copper tube/aluminum fin coils.All-aluminum construction offers superior protection against formicary corrosion and aluminum tube rubbing damage. Design allows for easier and faster cleaning.
  • Two Thermal Expansion Valves: Standard on all models for precise superheat control, reliability, and energy efficiency at all operating conditions.
  • High and Low Pressure Control: Standard on all models for refrigerant component protection and reliability.
  • Easily Accessible Control Box and Slide-Out Blower Section Allows for faster installability and serviceability.
  • Tested. Trusted. Tough. 100% Factory Run Tested.
  • PlusOne® Refrigerant Detection System™ Integrated, patented design providing system protection and homeowner peace-of-mind with low GWP refrigerant monitoring
Unit of Measure

Voltage

N/A 208/230 V

Frequency

N/A 60 Hz

Number of Phases

N/A 3

Outdoor Sound Rating

N/A 78 dB

Refrigerant Charge

N/A 80 oz2268 g

Minimum Circuit Ampacity

N/A 17

Minimum Overcurrent Protection Device Size

N/A 20

Maximum Overcurrent Protection Device Size

N/A 20

Shipping Weight

N/A 449 lb204 kg

Weight

N/A 199 kg439 lb

Nominal Cooling Capacity

N/A 36000 Btu/h10.55 kW

EER2

N/A 11.5

SEER2

N/A 15.2

Nominal CFM

N/A 1200 ft³/min566 L/s

AHRI Rated CFM

N/A 1230 ft³/min580 L/s

AHRI Net Cooling Capacity

N/A 35200 Btu/h10.32 kW

Net Sensible Cooling Capacity

N/A 26400 Btu/h7.74 kW

Net Latent Cooling Capacity

N/A 8800 Btu/h2.58 kW

Net System Power

N/A 3.32 kW

High Temp. Rating

N/A 34200 Btu/h10.02 kW

High Temp. Rating - System Power

N/A 2.64 kW

High Temp. Rating - System Power - COP

N/A 3.8

Low Temp. Rating

N/A 19400 Btu/h5.69 kW

Low Temp. Rating - System Power

N/A 2.47 kW

Low Temp. Rating - System Power - COP

N/A 2.3

HSPF2

N/A 7.2

Type

N/A Double-Stage Scroll

No. Stages

N/A 1

Fin Type

N/A MicroChannel

Tube Type

N/A MicroChannel

MicroChannel Depth

N/A 0.63 in16 mm

Face Area

N/A 16.48 ft²1.53 m²

Rows

N/A 1

FPI

N/A 16

Fin Type

N/A MicroChannel

Tube Type

N/A MicroChannel

MicroChannel Depth

N/A 1 in25.4 mm

Face Area

N/A 7.6 ft²0.71 m²

Rows

N/A 1

FPI

N/A 20

Refrigerant Control

N/A TXV

Drain Connection No.

N/A 1

Drain Connection Size

N/A 0.75 in19.0 mm

Type

N/A Propeller

No. Used

N/A 1

Diameter

N/A 24 in610 mm

Drive Type

N/A Direct

No. Speeds

N/A 1

CFM

N/A 4300 ft³/min2029 L/s

No. Motors

N/A 1

Horsepower

N/A 1/3 hp

Motor RPM

N/A 825

Type

N/A Constant Torque

No. Used

N/A 1

Diameter

N/A 11x9 in279x229 mm

Drive Type

N/A Direct

No. Speeds

N/A Multiple

No. Motors

N/A 1

Motor RPM

N/A 1200

Motor Frame Size

N/A 48

Type

N/A Field Supplied

Furnished

N/A No

No. Filters

N/A 2

Recommended Size

N/A 1x16x30 in25x406x762 mm

Depth

N/A 46 11/16 in

Width

N/A 55 25/32 in

Height

N/A 41 in

N/A

  • Two-Stage Scroll Compressors on all models: Provides maximum efficiency and quiet operation
  • MicroChannel Evaporator and Condenser Coil: Delivers superior performance with a robust surface, a decreased refrigerant requirement and is lighter than conventional copper tube/aluminum fin coils. All-aluminum construction offers superior protection against formicary corrosion and aluminum tube rubbing damage. The design allows for easier and faster cleaning
  • Two Thermal Expansion Valves: Standard on all models for precise superheat control, reliability, and energy efficiency at all operating conditions
  • High and Low Pressure Control: Standard on all models for refrigerant component protection and reliability
  • Filter Drier: Standard on all models
  • 100% Factory Run Tested
  • PlusOne® Refrigerant Detection System™: An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation — if excess refrigerant is detected
  • Rugged Base Rail: Contributes to improved installation and Handling
  • Easily Accessible Control Box and Slide-Out Blower Section: Allows for faster installability and serviceability
  • Side and Down Discharge Options Available: All models are shipped ready for horizontal applications
  • Double Sloped Evaporator Coil Drain Pan: Allows for complete water removal from the unit — contributing to improved indoor air quality
  • Louvered Condenser Compartment: Protects the coil against yard hazards and/or weather extremes
  • Supply and Return Air Openings: Feature a one-inch-tall flange to prevent water migration into the ductwork
  • Supplemental Electric Heating Option Available: Factory or field-installed, electrical heat strips, up to 15 kW with simplified single-point wiring, are available for periods of extreme weather conditions
  • Designing for sustainability with low GWP: For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems. This new requirement will result in a 78%1 lower GWP than previous-generation refrigerants with only minimal changes to system installation. For us, this is another step toward our continued sustainability goal of reducing greenhouse gas emissions, while still delivering an exceptional level of energy efficient, dependable comfort