CAD/BIM
- Two-Stage Scroll Compressors on all models: Provides maximum efficiency and quiet operation.
- MicroChannel Evaporator & Condenser Coil: Delivers superior performance with a robust surface, a decreased refrigerant requirement and is lighter than conventional copper tube/aluminum fin coils.All-aluminum construction offers superior protection against formicary corrosion and aluminum tube rubbing damage. Design allows for easier and faster cleaning.
- Two Thermal Expansion Valves: Standard on all models for precise superheat control, reliability, and energy efficiency at all operating conditions.
- High and Low Pressure Control: Standard on all models for refrigerant component protection and reliability.
- Easily Accessible Control Box and Slide-Out Blower Section Allows for faster installability and serviceability.
- Tested. Trusted. Tough. 100% Factory Run Tested.
- PlusOne® Refrigerant Detection System™ Integrated, patented design providing system protection and homeowner peace-of-mind with low GWP refrigerant monitoring
- Specifications
- Cooling Performance
- Heating Performance
- Compressor
- Outdoor Coil
- Indoor Coil
- Outdoor Fan
- Indoor Fan
- Filter
- Dimensions
- Features
Voltage |
N/A 208/230 V |
Frequency |
N/A 60 Hz |
Number of Phases |
N/A 1 |
Outdoor Sound Rating |
N/A 78 dB |
Refrigerant Charge |
N/A 80 oz2268 g |
Minimum Circuit Ampacity |
N/A 24 |
Minimum Overcurrent Protection Device Size |
N/A 30 |
Maximum Overcurrent Protection Device Size |
N/A 35 |
Shipping Weight |
N/A 449 lb204 kg |
Weight |
N/A 199 kg439 lb |
Nominal Cooling Capacity |
N/A 36000 Btu/h10.55 kW |
EER2 |
N/A 11.5 |
SEER2 |
N/A 15.2 |
Nominal CFM |
N/A 1200 ft³/min566 L/s |
AHRI Rated CFM |
N/A 1230 ft³/min580 L/s |
AHRI Net Cooling Capacity |
N/A 35200 Btu/h10.32 kW |
Net Sensible Cooling Capacity |
N/A 26400 Btu/h7.74 kW |
Net Latent Cooling Capacity |
N/A 8800 Btu/h2.58 kW |
Net System Power |
N/A 3.32 kW |
High Temp. Rating |
N/A 34200 Btu/h10.02 kW |
High Temp. Rating - System Power |
N/A 2.64 kW |
High Temp. Rating - System Power - COP |
N/A 3.8 |
Low Temp. Rating |
N/A 19400 Btu/h5.69 kW |
Low Temp. Rating - System Power |
N/A 2.47 kW |
Low Temp. Rating - System Power - COP |
N/A 2.3 |
HSPF2 |
N/A 7.2 |
Type |
N/A Double-Stage Scroll |
No. Stages |
N/A 1 |
Fin Type |
N/A MicroChannel |
Tube Type |
N/A MicroChannel |
MicroChannel Depth |
N/A 0.63 in16 mm |
Face Area |
N/A 16.48 ft²1.53 m² |
Rows |
N/A 1 |
FPI |
N/A 16 |
Fin Type |
N/A MicroChannel |
Tube Type |
N/A MicroChannel |
MicroChannel Depth |
N/A 1 in25.4 mm |
Face Area |
N/A 7.6 ft²0.71 m² |
Rows |
N/A 1 |
FPI |
N/A 20 |
Refrigerant Control |
N/A TXV |
Drain Connection No. |
N/A 1 |
Drain Connection Size |
N/A 0.75 in19.0 mm |
Type |
N/A Propeller |
No. Used |
N/A 1 |
Diameter |
N/A 24 in610 mm |
Drive Type |
N/A Direct |
No. Speeds |
N/A 1 |
CFM |
N/A 4300 ft³/min2029 L/s |
No. Motors |
N/A 1 |
Horsepower |
N/A 1/3 hp |
Motor RPM |
N/A 825 |
Type |
N/A Constant Torque |
No. Used |
N/A 1 |
Diameter |
N/A 11x9 in279x229 mm |
Drive Type |
N/A Direct |
No. Speeds |
N/A Multiple |
No. Motors |
N/A 1 |
Motor RPM |
N/A 1200 |
Motor Frame Size |
N/A 48 |
Type |
N/A Field Supplied |
Furnished |
N/A No |
No. Filters |
N/A 2 |
Recommended Size |
N/A 1x16x30 in25x406x762 mm |
Depth |
N/A 46 11/16 in |
Width |
N/A 55 25/32 in |
Height |
N/A 41 in |
N/A
|