1Factory installed on 4 and 5 ton models. For R-454B equipment with a refrigerant charge less than 3.9 lbs (≈1.8 kg or ≈62.6 oz), a refrigerant detection system is not required by the UL 60335-2-40 standard.
Voltage |
N/A 208/230 V |
Frequency |
N/A 60 Hz |
Number of Phases |
N/A 1 |
Sound Level |
N/A 81 dB |
Refrigerant Charge |
N/A 52 g1474 oz |
Minimum Circuit Ampacity |
N/A 20 |
Minimum Overcurrent Protection |
N/A 25 |
Maximum Overcurrent Protection |
N/A 30 |
Shipping Weight |
N/A 304 lb138 kg |
Weight |
N/A 277 lb126 kg |
Nominal Cooling Capacity |
N/A 24000 Btu/h7.03 kW |
EER2 |
N/A 10.6 |
SEER2 |
N/A 13.4 |
Nominal CFM |
N/A 753 ft³/min355 L/s |
AHRI Rated CFM |
N/A 750 ft³/min354 L/s |
AHRI Net Cooling Capacity |
N/A 22800 Btu/h6.68 kW |
Net Sensible Capacity |
N/A 16084 Btu/h4.71 kW |
Net Latent Capacity |
N/A 6716 Btu/h1.97 kW |
Net System Power |
N/A 2.15 kW |
Fin Type |
N/A Louvered |
Tube Type |
N/A MicroChannel |
MicroChannel Depth |
N/A 0.47 in11.99 mm |
Face Area |
N/A 10.1 ft²0.94 m² |
Rows |
N/A 1 |
FPI |
N/A 23 |
Fin Type |
N/A Louvered |
Tube Type |
N/A MicroChannel |
MicroChannel Depth |
N/A 0.81 in20.62 mm |
Face Area |
N/A 4.3 ft²0.4 m² |
Rows |
N/A 1 |
FPI |
N/A 20 |
Refrigerant Control |
N/A TX Valves |
Drain Connection No. |
N/A 1 |
Drain Connection Size |
N/A 1 in25.40 mm |
Type |
N/A Propeller |
No. Used |
N/A 1 |
Diameter |
N/A 24 in609.6 mm |
Drive Type |
N/A Direct |
No. Speeds |
N/A 1 |
CFM |
N/A 3400 ft³/min1604 L/s |
No. Motors |
N/A 1 |
Horsepower |
N/A 1/3 hp |
Motor RPM |
N/A 825 |
Type |
N/A FC Centrifugal |
No. Used |
N/A 1 |
Diameter |
N/A 10x9 in254x229 mm |
Drive Type |
N/A Direct |
No. Speeds |
N/A Multiple |
No. Motors |
N/A 1 |
Horsepower |
N/A 1/2 hp |
Motor RPM |
N/A 1050 |
Motor Frame Size |
N/A 48 |
Type |
N/A Field Supplied |
Furnished |
N/A No |
No. Filters |
N/A 1 |
Recommended Size |
N/A 1x20x16 in25x508x406 mm |
N/A
|